Midnite Solar Rosie Inverter — Equipment Type and Primary Applications
Equipment Type: Inverter/charger
Primary Applications: Off-grid and backup power systems using a 48 V battery bank; provides 120 VAC or 120/240 VAC from a single unit to support heavy loads with clean, true-sine-wave power.
Performance Specifications
- Output: up to 7,000 W (AC) from a 48 V DC source
- AC output: 120 VAC or 120/240 VAC (split-phase)
- Waveform: true sine wave
- Built-in charger: 120 A charging capability
- Battery management: Battery Temperature Sensor (BTS) for optimized charging
- Generator interface: auto start function for two-wire generators
- Cooling: quiet forced-air cooling; screened enclosure
- Monitoring/communications: two auxiliary I/Os, Canbus communications, remote battery voltage sensor
- Certifications: UL1741, UL458, CSA-listed
Safety Features and Certifications
- Certification marks: UL1741, UL458, CSA-listed
- Enclosure design: screened to resist dust, mud daubers, and debris
- Monitoring capabilities: remote battery voltage sensing and Canbus for safe operation and diagnostics
Installation and Maintenance Requirements
- Utilities: operates from a 48 V DC battery bank; 120/240 VAC output; 120 A charger
- Space/ventilation: ensure adequate ventilation for forced-air cooling; enclosure should allow unobstructed airflow
- Commissioning steps: connect battery, connect AC loads, enable auto start for generator, configure BTS/Canbus monitoring
- Preventive maintenance: periodic visual inspection of wiring and enclosure integrity; clean cooling paths and verify sensor connections
Warranty and Service Information
Warranty and service terms are not specified in the provided data.
Branding/References
- Manufacturer: MidNite Solar
- Model: Rosie
- Related references/datasheets: Manual (Download), Specs (Download)
- Optional/configurable accessories: Rosie E-Panel (AC/DC input breakers and inverter bypass); MidNite Wizbang Jr. and MNGP2 for state-of-charge tracking
Differentiators
- High-power, single-unit 7 kW solution at 48 V with true sine-wave output and split-phase 120/240 VAC
- Integrated 120 A charger plus auto-gen-start for two-wire generators; BTS sensor and Canbus/remote monitoring enable advanced system optimization