{"product_id":"enphase-iq-battery-5p-kit-iqbattery-5p-1p-na","title":"Enphase IQ Battery 5P Kit IQBATTERY-5P-1P-NA","description":"\u003ch2\u003eEnphase IQBATTERY-5P-1P-NA IQ Battery 5P Kit\u003c\/h2\u003e\n\u003cp\u003eIntroducing the Enphase IQBATTERY-5P-1P-NA, an advanced energy storage solution designed to enhance your solar system's performance and energy independence. This kit includes the IQ Battery 5P and all the components you need for seamless installation, allowing you to store excess solar energy for use when needed.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Storage:\u003c\/strong\u003e The IQ Battery 5P offers significant storage capacity, ensuring you have ample stored energy for various applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Energy Management:\u003c\/strong\u003e It allows you to optimize your energy usage, reducing reliance on the grid and lowering electricity costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable Backup Power:\u003c\/strong\u003e Enjoy peace of mind with backup power capabilities during grid outages, keeping your essential appliances running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration:\u003c\/strong\u003e The kit includes all components necessary for easy installation and integration with your existing solar system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Lifespan:\u003c\/strong\u003e The IQ Battery 5P is built to last, offering a reliable energy storage solution for years to come.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnology and Overview\u003c\/h2\u003e\n\u003cp\u003eThe Enphase IQBATTERY-5P-1P-NA utilizes advanced lithium iron phosphate (LiFePO4) battery technology to store and release energy efficiently. Its intelligent energy management system ensures optimal performance and maximizes the use of stored energy, whether you're self-consuming or selling excess energy back to the grid.\u003c\/p\u003e\n\u003ch2\u003eInstallation and Compatibility Overview\u003c\/h2\u003e\n\u003cp\u003eInstalling the IQ Battery 5P Kit is hassle-free, thanks to the included components and Enphase's user-friendly design. It seamlessly integrates with Enphase microinverters and other Enphase products, ensuring a smooth and efficient installation process.\u003c\/p\u003e\n\u003ch2\u003eBenefits and Applications Overview\u003c\/h2\u003e\n\u003cp\u003eThe Enphase IQBATTERY-5P-1P-NA offers numerous benefits, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduced electricity bills through efficient energy management\u003c\/li\u003e\n\u003cli\u003eReliable backup power during grid outages\u003c\/li\u003e\n\u003cli\u003eEnhanced sustainability by reducing reliance on fossil fuels\u003c\/li\u003e\n\u003cli\u003eIncreased self-consumption of solar energy\u003c\/li\u003e\n\u003cli\u003eCompatibility with residential and commercial solar systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts versatile applications range from residential homes to small businesses, providing energy resilience and cost savings.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable width=\"1070\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"326\"\u003e\u003cstrong\u003eMODEL NUMBER\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"744\"\u003eIQBATTERY-5P-1P-NA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe IQ Battery 5P system with integrated IQ Microinverters and battery management system (BMS) with\u003cbr\u003ebattery controller.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIQ Battery 5P unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P unit (B05-T02-US00-1-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eID cover and conduit cover\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P cover with two conduit covers for left-side and right-side of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBottom mounting bracket and top shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBottom mounting bracket for mounting bracket on the wall. One top shield required for UL9540A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM5 seismic screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo M5 seismic screws for securing battery unit on bottom bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM4 grounding screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo M4 grounding screws to secure top shield on bottom wall-mount bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM5 ID cover grounding screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo M5 ID Cover grounding screws for EMI\/EMC requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable ties\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSix cable ties for securing field cables to the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCTRL connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare CTRL connector without resistor for CTRL wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCTRL connector with resistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare CTRL connector with resistor for CTRL wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuick Install Guide (QIG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQIG for instructions on IQ Battery unit installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIQ8D-BAT-RMA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ8D-BAT Microinverter for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-T02-US00-1-3-RMA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P Battery unit for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-CX-0550-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P cover for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-PI-0550-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P pedestal mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-CP-096-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P conduit plates for field replacement. Includes one left-side and one right-side conduit plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-WB-0543-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P wall bracket for field replacement. Includes one wall-mount bracket and one top shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIQBATTERY-HNDL-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P lifting handles. Includes one left-side and one right-side lifting handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-ACFB-080-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P AC filter board for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-BMSNA-0490-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P BMS board for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-CANB-063-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P control communication board for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB05-NICS-0524-O, B05-NUCS-0524-O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIQ Battery 5P control switch preinstalled on the wiring cover for field replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOUTPUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e@240 VAC\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated (continuous) output power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.84 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak output power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.68 kVA (3 seconds), 6.14 kVA (10 seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal voltage\/Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240\/211-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal frequency\/Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\/57-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated output current (@240 VAC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak output current (@240 VAC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A (3 seconds), 25.6 A (10 seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower factor (adjustable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.85 leading...0.85 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum output overcurrent protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A per unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterconnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC round-trip efficiency^{2}\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemistry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLithium iron phosphate (LFP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2,500 meters (8,202 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall-mount or pedestal-mount (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsable capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 kWh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC round-trip efficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal DC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum DC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature range (charging)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C (-4°F to 122°F) non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature range (discharging)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 55°C (-4°F to 131°F) non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptimum operating temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 30°C (32°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemistry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLithium iron phosphate (LFP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e980 mm x 550 mm x 188 mm (38.6 in x 21.7 in x 7.4 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLifting weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e66.3 kg (146.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal installed weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.9 kg (174 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutdoor–NEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIQ8D-BAT Microinverter enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA type 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with IQ and M Series Microinverters, IQ System Controller 3\/3G, IQ Combiner 5\/5C, IQ\u003cbr\u003eGateway for grid-tied and backup operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWired control communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eServices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackup, Self-Consumption, TOU, and NEM Integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnphase Installer Platform and Enphase App monitoring options; API integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB, 3rd Ed.)\u003cbr\u003eCAN\/CSA C22.2 No. 107.1-16\u003cbr\u003eUL 9540, UL 9540A, UN 38.3, UL 1998, UL 991, NEMA Type 3R, AC156\u003cbr\u003eEMI: 47 CFR, Part 15, Class B, ICES 003\u003cbr\u003eCell Module: UL 1973, UN 38.3\u003cbr\u003eInverters: UL 62109-1, IEC 62109-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited warranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60% capacity, up to 15 years or 6,000 cycles³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Green Vista Living","offers":[{"title":"Default Title","offer_id":45264425517171,"sku":"USSE100-0438","price":2790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/9969\/3939\/files\/PROD_Image_USSE100-0438_17_01_2024_IQBATTERY-5P-1P-NA_Enphase.webp?v=1784490564","url":"https:\/\/ampereauthority.com\/products\/enphase-iq-battery-5p-kit-iqbattery-5p-1p-na","provider":"Ampere Authority","version":"1.0","type":"link"}